The Estates management record (EMR) collects information on both the Gross Internal Area (GIA) and Net Internal Area (NIA) of the higher education provider.

Contents: Gross Internal Area (GIA) | Net Internal Area (NIA) | Approaches for defining NIA | Inclusions and exclusions for NIA

Gross Internal Area (GIA)

GIA is the total area of buildings owned, occupied or maintained by the HE provider. GIA is measured to the internal face of the perimeter walls at each floor level (i.e. the footprint of the building excluding the width of the outside walls). It includes areas occupied by internal walls and partitions.

GIA should not be returned for commercial spaces that can be separately identified as a discrete area together with all associated costs, for example energy, waste, and emissions. Where the associated costs, such as waste and energy cannot be separately identified for a commercial space area, GIA for the commercial space area should be included in the EMR under Total GIA commercial space (SMGIACT). Providers should return the commercial space area as per other areas under the appropriate space measurement field, for example Residential GIA. Providers should also return the space under Total GIA commercial space. This way, the total commercial space area can be distinguished from Total GIA

Further guidance on returning commercial space can be found here.

Gross Internal Area

Net Internal Area (NIA)

NIA is the usable area within a building measured to the internal face of the perimeter walls at each floor level. NIA covers all areas which are used for a specific purpose.

NIA includes all areas which are used for a specific purpose, however it excludes those parts of buildings which enable them to function, such as corridors. These are classified as balance areas. Further examples of what is and is not included are listed below.

NIA should not be returned for commercial spaces that can be separately identified as a discrete area together with all associated costs, for example energy, waste, and emissions. Where the associated costs, such as waste and energy cannot be separately identified for a commercial space area, NIA for the commercial space area should be included in the EMR under Total NIA commercial space (SMNIACT). Providers should return the commercial space area as per other areas under the appropriate space measurement field, for example Residential NIA. Providers should also return the space under Total NIA commercial space. This way, the total commercial space area can be distinguished from Total NIA.

Further guidance on returning commercial space can be found here.

Approaches for defining NIA

There are two alternative approaches for the return of data on NIA:

HE Providers are able to use either approach to return NIA data to the EMR. NUA or Room Area Basis is however the preferred method of measurement, and in the longer-term HESA is aiming to standardise this approach.

1. NIA RICS method

The NIA RICS definitions are contained in the 'Code of Measuring Practice: A Guide for Property Professionals' (Sixth Edition), published by RICS. This method involves the measurement of the internal room area part way into the width of internal non-structural walls and partitions. It is demonstrated by the left-hand room in the diagram below.

2. Net Useable Area (NUA) or Room Area Basis

This method involves the measurement of the internal room area less the width of internal walls and partitions. It is demonstrated by the right-hand room in the diagram below.

RICS basis and room area basis

Inclusions and exclusions for NIA

The following table outlines examples of inclusions and exclusions for NIA.

Including Excluding
  • teaching and research rooms
  • atria
  • kitchens
  • workshops
  • built-in units, cupboards etc. occupying the useable area
  • stores
  • academic stores
  • porters' offices and kiosks
  • first aid rooms
  • staff common rooms
  • internal partition walls (e.g. fixed walls, de-mountable re-moveable screens)
  • ramps of lightweight construction to false floors
  • a floor area which contains a ventilation/heating grill
  • area occupied by skirting and perimeter trunking
  • areas served by internal non-structural walls, de-mountable partitions (whether or not permanent) etc. where the purpose of the division is partition of use (and not support) provided the area beyond is not used in common (by more than one occupier)
  • pavement vaults
  • notional lift lobby and similar areas where there are several functions using the area, such as meeting space, reception, or café
  • accommodation on NHS sites which is maintained or paid for
  • corridors and other circulation areas of a permanent nature (e.g. fire corridors, smoke lobbies etc.)
  • internal open-sided balconies or similar
  • internal structural walls, walls enclosing excluded areas, columns, piers, chimney berasts, vertical ducts, and other projections
  • stairways and stairwells (and voids over)
  • entrance lobbies (where the function is solely or primarily for entry/circulation)
  • foyers (where the function is solely or primarily for entry/circulation)
  • atria with clear height above, measured at base level only (where the function is solely or primarily for entry/circulation)
  • lifts
  • permanent lift lobbies, permanent lift rooms, liftwells, and lifts (and voids over)
  • lavatories and toilet lobbies
  • cloakrooms
  • cleaners' stores
  • cleaners' cupboards (as defined in the RICS definition)
  • covered areas (e.g. plant rooms, tank rooms, fuel stores which are housed in a structure of a permanent nature, whether or not above main-roof level
  • loading bays
  • ducts
  • permanent and continuous air-conditioning, heating, or cooling apparatus (as defined in the RICS definition)
  • boiler houses
  • calorifier chambers
  • fuel stores
  • accommodation on NHS sites which is neither maintained or paid for
  • internal car parks

In the diagram below the area in the red box is included in NIA. The area lying outside of the red box is excluded since the corridor and lavatory are classified as balance areas (NB “balance areas” are areas which allow the building to function)

Balance space

Need help?